chemiluminescence

Determination of laminar flame speed of methaneair flames at subatmospheric conditions using the cone method and CH* emission

Experimental measurements of laminar fl ame speed for premixed methane-air fl ames were carried out for different equivalence ratios at subatmospheric conditions, 852 mbar and 298 K. The fl ames were obtained using a rectangular port burner with a water cooler system necessary to maintain the temperature of the mixture constant. An ICCD camera was used to capture chemiluminescence emitted by OH-CH radicals present in the fl ame and thus defi ne the fl ame front.